Descripción de los productos
Industrial cooling fan is generally used in cold storage and cold chain logistics refrigeration environment. It is an evaporative cooling and ventilating unit that integrates cooling, ventilation, dust prevention, deodorization and humidification.
In addition to bringing fresh air and reducing temperature to public places such as enterprise workshops and business entertainment, the air cooler has an important feature – energy conservation and environmental protection. This is a kind of environment-friendly product without compressor, refrigerant and copper tube. The core of its main components – evaporative cortina húmeda (multilayer corrugated fiber composite) and 1.1KW main motor/are 1/8 of the power consumption of traditional central air conditioning, which can save more power for various industries.
The structure of the evaporative air conditioner is very simple. The water is conveyed to the upper part of the cortina húmeda through the water pump in the water tank. The water evenly wets the contact surface of the whole cortina húmeda. When the hot air passes through the cortina húmeda, the water absorbs a large amount of heat in the air to cool the air passing through the wet curtain. At the same time, it is filtered to make the sent air cool, moist and fresh.
The principle of the air cooler is to use water as the medium to let the water fully wet the “cortina húmeda” (corrugated fiber composite with high evaporation efficiency and high corrosion resistance formed by multiple processing and bonding). When the dry and hot air passes through the cortina húmeda, the water absorbs a large amount of heat in the air, and the flowing out is moist and cool air, which is the evaporation effect of liquid water.
Characteristics of commercial air coolers
Industrial air coolers suitable for various installation environments, excluding fixed installation and ventilation components.
-
A variety of models with single-phase speed regulation, three-phase single-speed, three-phase double-speed and three-phase multi-speed can provide different site requirements, and the three outlet installation modes of upper, lower and side air can facilitate the installation requirements in different places;
LCD controller and standard controller are easy to operate and the working state of the equipment is clear at a glance;
The fuselage is made of high-strength weather resistant polymer, which is UV resistant, corrosion resistant, aging resistant and deformation resistant;
The fan blades with professional design are adopted, with large air supply volume, low energy consumption, light weight, low noise and wide applicability;
Adopt high-quality fully enclosed aluminum shell motor, with good heat dissipation, high protection level, waterproof and moisture-proof;
Adopt automatic control water system and open water distributor to make the water flow uniform and smooth;
The high-efficiency evaporation filter screen is adopted, which has large evaporation capacity, good cooling effect and easy cleaning.
Construction of air cooler
The air cooler is mainly divided into cortina húmeda, shell, electric control, and other structures refer to the example figure
t is also known as water curtain, which is honeycombed and made from base paper. The production process is about sizing, drying, pressing corrugated, shaping, gluing, curing, slicing, grinding, and deodorizing.
In China, there are usually three types of wave height: 5mm, 7mm and 9mm, and the ripple is 60 ° × 30 ° staggered, 45 ° × 45 ° staggered.
The high-quality cortina húmeda is made of a new generation of polymer materials and space cross-linking technology. It has the advantages of high water absorption, high water resistance, mildew resistance and long service life. Moreover, the evaporation is larger than the surface, and the cooling efficiency is more than 80%. It does not contain surfactants, and naturally absorbs water, with fast diffusion speed and lasting efficiency. A drop of water can diffuse in 4-5 seconds. The natural water absorption of the same international industry standard is 60~70mm/5min or 200mm/1.5hour.
The high-quality cortina húmeda also does not contain phenol and other chemicals that are easy to cause skin allergy. It is non-toxic and harmless to human body when installed and used. It is green, safe, energy-saving, environmentally friendly and economical.
Features of air cooler
① Low investment and high efficiency (only 1/8 power consumption of traditional central air conditioning).
② You can use the air cooler without closing the doors and windows.
③ It can replace the indoor turbid, muggy and smelly air and exhaust it outside.
④ The power consumption is low, and the power consumption of each unit is 1.1 degrees per hour, without refrigerant (Freon).
⑤ Air supply volume of each air cooler: 6000-80000 cubic meters.
⑥ Each cold air covers an area of 100-130 square meters.
Features of steam type air cooler:
-
The cooling effect is obvious: in humid areas, the cooling effect can reach about 5-9 ℃; In particularly hot and dry areas,
The cooling range can reach 10-15 ℃.
-
The investment cost is low and does not occupy the building area. Compared with the traditional compressor air-conditioning system, the cost is less than half.
-
Keep the indoor air clean, clean and sanitary.
-
Easy maintenance and installation: the system is simple, easy to install and maintain quickly, without professional maintenance personnel.
-
Prevent air drying: It can moisturize the skin and has certain benefits for the skin.
- Easy to maintain and install without professional maintenance personnel.
Descripción de los productos
Ámbito de aplicación:
-
Textile, machinery, ceramics, fine chemicals, metallurgy, glass, hardware, leather and other manufacturing industries;
-
Electroplating, electronics, shoemaking, printing and dyeing, plastics, clothing, printing, packaging, food and other processing industries;
-
Hospital, waiting room, school, waiting room, supermarket, laundry;
-
Kitchen, food market, large entertainment center, underground parking lot, station and other public places;
Precautions for use of air conditioner
In case of long-distance transportation, protective measures shall be taken to prevent the products from being damaged upon arrival. If a wooden frame is added to the package of the air cooler to protect it from heavy pressure and collision, it should be handled with care; Before installation and operation, the machine shall be checked and the bearing position shall be lubricated; The power supply shall meet the design specifications, and the voltage deviation shall not exceed the rated voltage of more than 10V; When the air cooler is working, it is not allowed to open the shutter with external force.
The installation location of the air cooler affects the air supply volume and the freshness of the air.
When installed outdoors, ensure fresh air circulation. The host can be installed in a place with good ambient air quality as far as possible. Do not install it at the exhaust port with peculiar smell.
When installed on the wall, on the roof or on the outdoor terrace, the air duct should be avoided to be too long. Generally, the length of 15-20 meters is the best, and the number of air duct elbows or no elbows should be reduced as much as possible.
When the main engine is running, open a certain area of doors or windows for ventilation. If there are not enough doors and windows, install an exhaust fan and ensure that the exhaust volume is 80% of the total air supply volume of the air cooler.
The main frame of the cooling fan shall be welded with steel structure, and its structure shall support twice the weight of the whole body and maintenance personnel.