Manufacturer of temperature control equipment logo
  1. Home
  2. /
  3. Products
  4. /
  5. Electric heater

Electric heater

Fan heater is a combined unit composed of fan, motor and radiator. It is applicable to various types of workshops where the air can be recycled. When the air does not contain dust and flammable gas, it can be used for heating by circulating air.

Products Description

 

Electric heater

The heater is a combined unit composed of ventilator, motor and radiator. It is applicable to various types of workshops where the air is allowed to be recycled. When the air does not contain dust and flammable gas, it can be used for circulating air heating.

The heater is mainly composed of air heater and fan. The air heater dissipates heat, and then the fan sends it out, so that the indoor air temperature can be adjusted. The air heater is composed of spiral finned tubes. For example, the heat exhaust pipe of steam heater is wrapped with aluminum strip special equipment with a wall thickness of Φ 21.5 On the seamless boiler pipe, the sheet spacing is 2.5mm, the exhaust pipe and the heat medium flow pipe are of integral welded structure, and the working pressure of the heater is below 0.8MPa.

Packaging and logistics freight

 

  • Port: Shandong, China

  • Incoterms: FOB, CFR, CIF. EXW

  • Payment method: letter of credit, telegraphic transfer

  • Certification: CE, ISO, UL, QS, GMP

  • Warranty period: 1 year

  • Average lead time: peak season lead time: 3-6 months, off-season lead time: 1-3 months

Electric heater

 

Scope of application

 

Your advantages with igus® polymer plain bearings and energy chains:
  • Factory workshop, material warehouse, moisture-proof drying, local heating

  • Construction site, road and bridge, cement maintenance, field heating

  • Oil drilling, coal mining area, deicing and antifreezing, equipment insulation

  • Railway airport, yacht ship, paint drying, construction insulation

  • Military vehicle equipment, command tent, mobile heating, convenient heating

  • Greenhouse, venue and club, clean heat, fast heating

Electric heater

 

Maintenance skills

 

Electric heater

After a period of driving, there is a layer of foreign matter and dust on the surface of the water tank of the heater. If it is not cleaned, the heat dissipation will be affected. After a long time of operation, the blower motor should be maintained and replaced. This operation process must be judged and maintained by professional personnel. It is not allowed to disassemble the motor without permission, which may easily cause short circuit and motor not rotating, or burn the fuse, or seriously cause harness burning and fire. The ventilation pipe of the motor cannot be removed, which is easy to cause overheating and burning of the motor. The variable speed resistance can change the gear of the motor. If the first and second gears are used for a long time, the resistance will burn out and affect the normal use. If this problem is found, it should be replaced in time. After the operating system is used for a long time, the control cable is prone to aging and deformation, which makes the operation inflexible or not in place. Do not move it hard to avoid damage to parts. If this problem is found, it should be judged at the maintenance station and repaired and replaced according to the specific situation. The ventilation pipes, namely the No. 1 and No. 2 rubber pipes of the heater, are easily aged and cracked due to long-term use under high temperature. If problems are found, they should be replaced in time to avoid water leakage, resulting in high water temperature and deformation of the engine cylinder head. Replace the rubber hose with the rubber hose provided by Xiali Car. The inferior rubber hose is not corrosion resistant.

During the use of the device, attention should be paid to the following points: when the temperature is below 0 ℃ in winter, there will be a layer of ice and frost on the front windshield. Start the engine, raise the water temperature to above 40 ℃, put the control in the defrosting position according to the sign, put the circulation in the indoor circulation position, turn on the blower motor and put it in the third gear position, at this time, the motor speed is the highest, and make it run for 3-5 minutes, and then put the gear in the first and second gear positions according to the defrosting situation. During this period, the driver should not leave the cab. If the motor does not rotate, immediately shift the motor to the closed position to avoid burning the variable speed resistor. When the outside temperature is low and there are many drivers and passengers in the cab, the glass will frost. You can put the control in the defrost position and the outdoor circulation position, and the motor can be put in the first or second gear position, so that the frost can be removed. When there is no wind, sand and dust outside, the circulation can be put outside to make the cab air fresh. If there are sandstorm and dust or the weather is too cold, put the circulation into the room to avoid sandstorm and dust entering the cab.

Safety warning

 

  • Do not place the electric heater directly next to the power socket. Do not touch the heating element inside the heater with your hands to avoid danger!!

    Do not cover the electric heater when it is heating. If it is covered, the heater will overheat· It is not allowed to use the heater in any water or wet place, such as sink, bathtub, swimming pool, etc. If there is water dripping into the running heater, it may cause short circuit or electric leakage of the machine.

    The electric heater should be stored in a safe place away from inflammables, and the minimum distance should not be less than 0.5 meters.

    Do not use it in places full of dust and gasoline, paint thinner and other flammable and explosive dangerous goods to prevent danger.

    Do not use electric heater near curtains, door curtains and textiles to avoid fire.

    Pay special attention to safety when applying the heater in places where children and animals often appear.

    Before using the electric heater, check whether the voltage and current meet the requirements of the machine.

    The electric heater must use the socket with grounding, and the wire must meet the requirements,

    An electric shock occurs in an emergency.

    Do not unplug the power cord directly. After turning off the machine, wait for the machine to cool down before unplugging the power cord.

    Please unplug the power when the electric heater is not applicable.

 

 

 

INQUIRY NOW

Leave A Message

You Might Also Like

DSC01271 1679896309594
Industry information

What considerations should businesses keep in mind when selecting China’s FRP anti-corrosion fans to ensure optimal performance and corrosion resistance?

Learn More
86883e5827e6546e1ae5d9b5e774 1679886650291
Industry information

What are the key characteristics of a high-quality negative pressure fan, and how do they contribute to effective ventilation and cooling in various settings?

Learn More
u13735616863029299073fm199aG 1675153698297
Industry information

What are the key features and benefits of high-quality circulating exhaust cooling fans for industrial and commercial applications, and how do they contribute to improved ventilation and temperature control?

Learn More
u40114489653401262434fm253fg 1679887215669
Industry information

What are the key factors that poultry farmers and industrial facilities should consider when selecting a negative air exhaust fan supplier to ensure effective air circulation and odor control?

Learn More
u10619098163078841448fm199aG 1679900741230
Industry information

What materials and manufacturing processes are commonly used by honeycomb paper wet curtain suppliers, and how do these factors affect product performance and durability?

Learn More
DSC01282 1679896620006
Industry information

What are the key factors to consider when choosing a cow shed cooling fan supplier?

Learn More
DSC01270 1679896250918
Industry information

What are the advantages of using Fiberglass Reinforced Plastic (FRP) fans compared to traditional metal fans in industrial applications?

Learn More
fe001bee4e34e2235702049f563a 1679889040421
Industry information

Which types of crops or plants are best suited for cultivation using evaporative cooling techniques in greenhouses?

Learn More
ba454b06ee1de9290e3a38307f64 1679886477544
Industry information

Choosing the Right Energy-Saving Negative Pressure Fan Supplier for Your Business: Key Considerations

Learn More
bb3677b33fb60df75cf473f9e9a2 1679886100388
Industry information

What are the key factors to consider when choosing a reliable negative pressure exhaust fan supplier for agricultural or industrial ventilation systems?

Learn More
36370a2939f3308c59ca99631f29 1679886715069
Industry information

What are the Key Factors to Consider When Setting up a Successful Sheep Breeding Farm Fan?

Learn More
weibiaoti1yingwen 1679901347307
Industry information

Can you provide insights into the applications and industries that benefit most from the use of high-quality cooling water curtain paper?

Learn More